https://api.sam.gov/prod/opportunities/v1/noticedesc?noticeid=414fd6c239dd4438b84bf53c1592af8d
AI Summary
The solicitation (FA813726R0018) awards three contracts to replace roofs on four Tinker AFB buildings (B1049, B7038, B414, B6601) with a total value of $1‑5 million. Work will be performed concurrently and is limited to Small Business MAC BOA holders. The contractor must provide key personnel—including a Project Manager, Quality Control Manager, Site Safety and Health Officer, and Superintendent/Foreman—and obtain required badges. Comprehensive quality‑control, health‑and‑safety (OSHA VPP compliance, emergency evacuation, mishap reporting), bio‑environmental, and outage management programs are mandated, along with specific project requirements such as government occupancy, defined working hours, phased execution, FOD awareness and prevention training, airfield‑operations coordination, and affirmation of procurement and environmental‑management surveys. The work is not located in a controlled/restricted area. Pre‑construction duties include formal correspondence, standardized documentation (reports, submittals, drawings) with prescribed file‑naming conventions, and a construction schedule that follows the required format, is updated regularly, and coordinates with government activities. Progress reporting, maintenance of working documents, and adherence to minimum guidance documents (architectural, structural, mechanical, electrical, and Unified Facilities Guide specifications) are required. An editable submittal register must be reviewed, revised, and submitted for approval within ten calendar days of the Notice to Proceed, with the contractor recommending removal of inapplicable items and adding any additional submittals. Where guide specifications present multiple options, the contractor must issue RFIs for clarification per Tinker AFB standards, UFCs, and the SOW.
Details
- Notice ID
- 414fd6c239dd4438b84bf53c1592af8d
- Solicitation Number
- FA813726R0018
- NAICS Code
- 238160
- Classification Code
- Z2AZ
Want to track opportunities like this?
Sign up for Kontratar to get AI-powered opportunity matching, ranking, and alerts.
Get Started FreeRelated opportunities
- RF Roof Replacement Project
ENERGY, DEPARTMENT OF.ENERGY, DEPARTMENT OF.PRINCETON LAB - DOE CONTRACTOR
- Fenn Ranger Station roofing replacement
AGRICULTURE, DEPARTMENT OF.FOREST SERVICE.NEZ PERCE-CLEARWATER NFS
- RF Roof Replacement Project
ENERGY, DEPARTMENT OF.ENERGY, DEPARTMENT OF.PRINCETON LAB - DOE CONTRACTOR
- NY MONTEZUMA NWR MAIN SHOP ROOF
INTERIOR, DEPARTMENT OF THE.DEPARTMENTAL OFFICES.FWS CONTRACTING ACTIVITY
- Z--SLV-CB PUMPING PLANT ROOF
INTERIOR, DEPARTMENT OF THE.BUREAU OF RECLAMATION.UPPER COLORADO REGIONAL OFFICE
- RF Roof Replacement Project
ENERGY, DEPARTMENT OF.ENERGY, DEPARTMENT OF.PRINCETON LAB - DOE CONTRACTOR
- WWYK250063 - INSTALL REACT VII FACILITY, B9001, POST V19
DEPT OF DEFENSE.DEPT OF THE AIR FORCE.AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8137 AFSC PZIOC
- WWYK260004 - REPAIR STRUCTURAL INTEGRITY, B1134, POST 34 & NORTH WALL
DEPT OF DEFENSE.DEPT OF THE AIR FORCE.AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8137 AFSC PZIOC