MAHG231025 Repair Holbrook Manor HVAC, B7320
Posted
Apr 27, 2026
Due Date
Apr 27, 2026
Location
Biloxi, Mississippi
Description
https://api.sam.gov/prod/opportunities/v1/noticedesc?noticeid=acb89dc136744e5f8ce5768a3bc5ba31
AI Summary
The solicitation requires the contractor to develop and manage a detailed construction schedule that includes all mandatory activities, definable features of work (DFOWs), and long‑lead procurement items, and to submit a preliminary Schedule of Values (SOV) with the proposal for Contracting Officer approval. Pre‑construction submittals (SD‑01) must be delivered within ten calendar days of notice to proceed (or fifteen days of award for contractor‑approved items), and all submittals classified “G” or “S” require government approval. The contractor must also provide contract‑specific QA/QC and Safety Plans, comply with the latest USACE EM 385‑1‑1 safety standards, and ensure the Site Safety and Health Officer meets EM 385‑1‑1 qualifications (the SSHO may also serve as Quality Control Manager). Additional deliverables include as‑built architectural, electrical, plumbing, and structural drawings, a Schedule of Values updated per CO direction, and a comprehensive submittal register. The Contracting Officer retains final schedule approval, and a Scheduling Expectations Kickoff Meeting (SEKO) will be held to review schedule requirements and expectations. Key project‑specific requirements include confirming that a single superintendent can fulfill supervision, safety, and QA/QC roles; that the project is tax‑exempt; that attic areas above each wing are released per phasing and can be worked independently; that motorized outside‑air dampers are not being replaced; and that mold testing, air sampling, and remediation are excluded from scope. The contractor must also accommodate additional site visits for subcontractors and provide the requested as‑built drawings for reference. Performance will be evaluated on past performance quality, schedule timeliness, and management capability, using the provided rating scales.
Details
- Notice ID
- acb89dc136744e5f8ce5768a3bc5ba31
- Solicitation Number
- FA301026R00032
- NAICS Code
- 238220
- Classification Code
- N041
Want to track opportunities like this?
Sign up for Kontratar to get AI-powered opportunity matching, ranking, and alerts.
Get Started FreeRelated opportunities
- J041--Condensate Pump Replacement
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.241-NETWORK CONTRACT OFFICE 01 (36C241)
- Santee Lab HVAC Replacement
AGRICULTURE, DEPARTMENT OF.FOREST SERVICE.USDA FOREST SERVICE
- Waterline Break USCG ANT Saugerties
HOMELAND SECURITY, DEPARTMENT OF.US COAST GUARD.BASE BOSTON
- L7WC02_ B670 Paint Booth and HVAC
DEPT OF DEFENSE.DEPT OF THE AIR FORCE.AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8571 MAINT CONTRACTING AFSC PZIM
- Head Inspection and Repair Services of Harbor Security Boats in support of Commander Navy Region Southwest
DEPT OF DEFENSE.DEPT OF THE NAVY.NAVSUP.NAVSUP GLOBAL LOGISTICS SUPPORT.NAVSUP FLC SAN DIEGO.NAVSUP FLT LOG CTR SAN DIEGO
- FCC Allenwood - Repair Ground & Elevated Water Tanks - FCC
JUSTICE, DEPARTMENT OF.FEDERAL PRISON SYSTEM / BUREAU OF PRISONS.FAO
- John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)
DEPT OF DEFENSE.DEPT OF THE ARMY.US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION NORTHWESTERN.ENDIST PORTLAND.W071 ENDIST PORTLAND
- Replacement of 10 Ton HVAC Unit, Bldg.11, PR ANG
DEPT OF DEFENSE.DEPT OF THE ARMY.NATIONAL GUARD BUREAU.JFHQ USPFO PR.USPFO PR PROCUREMENT.W7PA USPFO ACTIVITY PRANG 156