Upgrade Doors and Hardware - Iowa City VAMC
Posted
Sep 3, 2025
Due Date
Sep 12, 2025
Location
Iowa City, Iowa
Description
https://api.sam.gov/prod/opportunities/v1/noticedesc?noticeid=e050d784236747c1894c2fa085baeedb
AI Summary
Here's a breakdown of the key information regarding UTP cabling and related requirements, extracted from the provided text: **UTP Cable Specifications:** * **Type:** 100-ohm, 4-pair UTP (Unshielded Twisted Pair) * **Configuration:** Formed into 25-pair binder groups covered with a blue thermoplastic jacket. * **Performance Standards:** Must comply with: * ICEA S-90-661 (mechanical properties) * TIA/EIA-568-B.1 (performance specifications) * TIA/EIA-568-B.2 (Category 6A) * **Listing/Labeling:** Cables must be listed and labeled by a Nationally Recognized Testing Laboratory (NRTL) to comply with UL 444 and NFPA 70, with one of the following types: * Type CM (General Purpose Communications) * Type CMP (Plenum Rated) * Type CMR (Riser Rated) * Type CMX (Limited Purpose) * Type MP or MPG (Multipurpose) * Type MPP (Multipurpose Plenum) * Type MPR (Multipurpose Riser) **UTP Cable Hardware:** * **Connecting Hardware:** IDC (Insulation Displacement Connector) type, designed for punch-down caps/tools. Must be of the same or higher category as the cable. * **Connecting Blocks:** 110-style for Category 6A. The quantity provided must exceed the number of cables terminated by 25% to account for spares. **Additional Requirements (From broader context):** * **Conduit:** All cabling locations must utilize conduit systems as outlined in Division 28 (unless a waiver is approved). * **Backboards:** Plywood, fire-retardant treated, dimensions: ¾" x 48" x 96". * **Inspection:** Work must be inspected by the Building Official and must be included in the Contractor's CQC plan. * **Environmental Conditions:** UTP and connecting materials should not be delivered or installed until wet work is completed and the temporary HVAC system is operating to maintain appropriate humidity and temperature.
Details
- Notice ID
- e050d784236747c1894c2fa085baeedb
- Solicitation Number
- 36C26325B0015_1
- NAICS Code
- 236220
- Classification Code
- Z1DA
Want to track opportunities like this?
Sign up for Kontratar to get AI-powered opportunity matching, ranking, and alerts.
Get Started FreeRelated opportunities
- Z1DA--FY27 NRM - VISN Base Install Roof Equipment Railings - 539-22-206
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.250-NETWORK CONTRACT OFFICE 10 (36C250)
- Z2DA--FY27 NRM - VISN CSI Base Fluoroscopy Room C216o Prep - 539-CSI-208
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.250-NETWORK CONTRACT OFFICE 10 (36C250)
- Z1DA--FY27 NRM - VISN Base Modernize Nurse Call - 539-23-101
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.250-NETWORK CONTRACT OFFICE 10 (36C250)
- F-15 Aerospace Ground Equipment (AGE) Facility, Vandenberg SFB
DEPT OF DEFENSE.DEPT OF THE ARMY.US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION SOUTH PACIFIC.ENDIST LOS ANGELES.W075 ENDIST LOS ANGELES
- Z1DA--460-26-999 | Condenser Water Piping Modification
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.244-NETWORK CONTRACT OFFICE 4 (36C244)
- Robins RAPID Construction OTA Progressive Design Build Fiber Replacement
DEPT OF DEFENSE.DEPT OF THE AIR FORCE.AIR FORCE MATERIEL COMMAND.AIR FORCE SUSTAINMENT CENTER.FA8501 OPL CONTRACTING AFSC/PZIO
- F-15 Aerospace Ground Equipment (AGE) Facility, Vandenberg SFB
DEPT OF DEFENSE.DEPT OF THE ARMY.US ARMY CORPS OF ENGINEERS.ENGINEER DIVISION SOUTH PACIFIC.ENDIST LOS ANGELES.W075 ENDIST LOS ANGELES
- Modernize 6N Inpatient Restrooms (Swing for 3N)
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.256-NETWORK CONTRACT OFFICE 16 (36C256)